Seq# | Description | Implement | Flags | Cardinality | Length | C.LEN | Vocabulary | Data Type |
---|---|---|---|---|---|---|---|---|
DLT | ||||||||
1 | Normal Range | [0..1] | NR | |||||
2 | Numeric Threshold | # | [0..1] | 4 | NM | |||
3 | Change Computation | [0..1] | 0523 | ID | ||||
4 | Days Retained | # | [0..1] | 4 | NM |
Components: <Normal Range (NR)> & <Numeric Threshold (NM)> & <Change Computation (ID)> & <Days Retained (NM)>
Subcomponents for Normal Range (NR): <Low Value (NM)> ^ <High Value (NM)>
Definition: Describes the information that controls delta check warnings.
Note: Replaces the CM data type used in section 8.8.4.9 – OM2-9, as of v 2.5.
Definition: Specifies the normal interval of the reference data.
Definition: The numeric threshold of the change that is detected.
For example the threshold may be set to 10.
Definition: Specifies if the change is computed as a percent change or as an absolute change. Refer to HL7 Table 0523 - Computation Type for valid values.
Definition: The length of time in days that the value is retained for computing delta checks.